제품설명
MONO ZetaViewⓇ(PMX-130)
ZetaView® 는 브라운 운동을 하거나 마이크로 전기영동에 의해 움직이는 개별 입자를 Camera로
직접 촬영하여 나노 입자의 크기, 제타 전위, 입자 개수를 분석하는 시스템입니다.
저농도 시료의 분석이 용이하며 분석 전 Auto-Alignment와 Auto-Focusing 등의 기능을 통해
사용자간 데이터 편차를 제거하여 정확하고 신뢰성 있는 분석이 가능합니다.
제품 특징
1. 1 Click Auto Focusing - 사용자간 편차 없음
2. 1 Click 레이저 변경 및 형광 모드 전환
3. 11 positions / min. 스캐닝 분석
4. 제타 전위(Zeta Potential) 분석 가능
5. Intensity 차이로 한 샘플 내 혼합 입자 크기 구분 가능
6. Pump를 통한 Sample Cell 자동 세척
형광 분석
분석 범위
상세사양
Measurement principles |
Precision-engineered motorized scanning Nanoparticle Tracking Analysis (NTA) instrument for tracking the movement of individual visualized nanoparticles in suspension Real-time visualization of Brownian Motion and electrophoretic mobility, for measuring size, concentration and zeta potential in scattering and fluorescence modes. Four simultaneous aligned and software-controlled lasers for fluorescence measurements Software controlled emission filter changer for quick changes between the fluorescence measurements Fast scanning to acquire and analyze typically 1000 particles in ~ 1 minute Software-controlled pumps for flushing and sample sub-dosing |
Samples |
Nanoparticles suspended in polar liquids (e.g. water, alcohols) for size, concentration, fluorescence and zeta potential studies |
Optical layout |
90° laser scattering video microscope with x10 magnification Automated alignment and focusing of laser and microscope" |
Camera |
High sensitive CMOS camera 640 x 480 pixels Variable frame rate from 1 to 60 Hz for optimum resolution and fast acquisition" |
Fluorescence Filter sets |
Software controlled, automated filter wheel with four long-pass fluorescence emission filters(LWP) with cut-off at 430 nm / 500 nm / 550 nm / 680 nm [QUATT] Bandpass filter available on request |
Cell Assembly |
Z-NTA slide-in assembly for size, concentration and dual fluorescence measurements plus zeta potential experiments in aqueous and organic solvents with pumps for 2 different liquids/buffers – for rinsing and sub-dosing experiments, electrical field sensing |
Cleaning |
Cell cleaning recommended weekly – cell resistant to >1000 brush cleanings Cleaning of driver electrodes required after more than 1000 zeta potential runs Cleaning kit and basic replacement parts included in delivery |
Temperature Range/Control |
Working external temperature range: 5°C ~ 45°C Sample temperature control : Peltier temperature control from RTP -5°C ~ 55°C with dew-point sensing |
Communication |
Software provided on pre-configured PC, communication via Ethernet |
Quality Control |
Cell quality check, daily performance check, outlier control with automatic Grubbs statistical analysis of measurement data |
Live Monitoring |
Fully customizable SOPs for different samples / applications |
Standard Operating Procedures (SOP) |
Cell quality check, daily performance check, outlier control with automatic Grubbs statistical analysis of measurement data |
Analysis and Reports |
Data Analysis in scatter and / or fluorescence mode: particle size distribution profiles, concentration, overlays and averaging, scatter plots, zeta-potential distribution profiles, sub-population analysis Data export format: AVI, TXT, CSV, FCS PDF reports containing key results |
Size/Concentration |
Concentration range: 105 ~ 109 particles/ml Particle size: 10nm ~ 2000nm (dependent on sample and laser selection) Accuracy: ±5nm (for 100nm polystyrene latex) Reproducibility: ±2nm (for 100nm polystyrene latex) |
Fluorescence |
Concentration range: 105 ~ 109 particles/ml Particle size: 10nm ~ 2000nm (dependent on fluorescent dye and laser selection) Accuracy: ±5nm (for 100nm polystyrene latex) Reproducibility: ±2nm (for 100nm polystyrene latex) |
Zeta Potential Reports |
Working range: -500mV ~ +500mV Concentration range: 106 ~1010 particles/ml Conductivity range: 3µS/cm ~ 15mS/cm Accuracy: ±4mV (for alumina zeta potential standard) Reproducibility: ±2mV (for alumina zeta-potential standard) |
General |
Minimum sample quantity: 500μl of sample at 10 particles/ml pH range: 1 ~ 13 Temperature: 5°C ~ 45°C (external temperature) Sample volume visualised and tracked by the camera for a single measurement: 11 x 3nL |
Reference Materials |
Nominal 100 nm reference suspension for size Two nominal 100 nm reference suspensions for fluorescence Nominal +50mV reference suspension for zeta potential |
Physical |
Footprint (W x D x H) : 20 x 30 x 25cm Weight : 8.5kg (main unit, PC extra) Shipping box with standard content : 48 x 62 x 63cm ; 22kg |
Electrical |
90~240V, 47~63Hz, 50VA |
제품관련 자료